42
Your Cart

PRODUCT INFO

Direct Spark Ignition (DSI) Control Board

The ICM292A is a low-cost DSI gas ignition control that replaces the following Rheem model: 62-24140-04. The ICM292A has incorporated LED diagnostics to assist in troubleshooting.

Fault code information can be found in the application guide. Please refer application guide with the furnace installation manual for future reference.

DETAILS:

  • Low cost form, fit and functional replacement for Rheem: 62-24140-04
  • Direct Spark Ignition (DSI) control
  • Microprocessor-based
  • Controls induced draft and indoor blower motor; humidifier output, spark ignitor and gas valve
  • Monitors timing, trial for ignition, flame sensing and lockout
    100% lockout safety feature
  • Compatible with LP or natural gas
  • Status LEDs for fault codes to aid in troubleshooting 

Replaces: Rheem: 62-24140-04

General Information 
Control Voltage: 24 VAC (18-30 VAC), 60 Hz
Line Voltage: 115 VAC, 60 Hz
Power cons:   30 seconds 
Trial for ignition: 7 seconds
Retries: Two groups of two, 30 seconds delay within the group and 3 minutes delay between group
Lockout: 1 hour
Post-purge: 90, 120, 160 and 180 seconds
Power:  24 VAC and COM
Thermostat interface:  R, W, Y and G

Reviews

There are no reviews yet.

Be the first to review “ICM ICM292A Furnace Control Boards, Rheem Replacement Boards”

Your email address will not be published. Required fields are marked *