PRODUCT INFO
Direct Spark Ignition (DSI) Control Board
The ICM292A is a low-cost DSI gas ignition control that replaces the following Rheem model: 62-24140-04. The ICM292A has incorporated LED diagnostics to assist in troubleshooting.
Fault code information can be found in the application guide. Please refer application guide with the furnace installation manual for future reference.
DETAILS:
- Low cost form, fit and functional replacement for Rheem: 62-24140-04
- Direct Spark Ignition (DSI) control
- Microprocessor-based
- Controls induced draft and indoor blower motor; humidifier output, spark ignitor and gas valve
- Monitors timing, trial for ignition, flame sensing and lockout
100% lockout safety feature - Compatible with LP or natural gas
- Status LEDs for fault codes to aid in troubleshooting
Replaces: Rheem: 62-24140-04
General Information | |
Control Voltage: | 24 VAC (18-30 VAC), 60 Hz |
Line Voltage: | 115 VAC, 60 Hz |
Power cons: | 30 seconds |
Trial for ignition: | 7 seconds |
Retries: | Two groups of two, 30 seconds delay within the group and 3 minutes delay between group |
Lockout: | 1 hour |
Post-purge: | 90, 120, 160 and 180 seconds |
Power: | 24 VAC and COM |
Thermostat interface: | R, W, Y and G |